top of page
Recent Pictures of Building Defects and Timber Pests

01
Leakage from bathroom
Leakage from bathroom

02
Leakage from bathroom

03
Undersized box gutters with no overflow provisions almost always fail

04
Leakage from galvanized water pipes

05
Deteriorated roof sarking

06
Poor subfloor drainage resulting in concrete pier rotation

07
Poor subfloor drainage

08
No roof flashings installed at the chimney

09
Mold growth to timber floor joists where subfloor ventilation is poor

10
Deteriorated timber flooring due to poor subfloor ventilation and fungal growth

11
Deteriorated metal roofing and water proofing membrane

12
Undersized box gutters with no overflow provisions almost always fail

13
Ponding water to box gutter could cause gutters to deteriorate prematurely

14
Deteriorated Box gutter due to ponding water caused by negative fall

15
Leakage from water pipe in the wall cavity

16
Mold growth to flooring due to poor subfloor ventilation

17
Mold growth and deterioration to flooring due to poor subfloor ventilation

18
Mold growth and deterioration to flooring due to poor subfloor ventilation

19
Mold growth to carpet due to prolonged exposure to damp conditions

20
Leakage frombathroom

21
Mold growth and deterioration to flooring due to poor subfloor ventilation

22
Mold growth and deterioration to flooring due to poor subfloor ventilation

23
Mold growth and deterioration to flooring due to poor subfloor ventilation

24
Mold growth and deterioration to flooring due to poor subfloor ventilation

25
Mold growth and deterioration to flooring due to poor subfloor ventilation

26
Mold growth and deterioration to flooring due to poor subfloor ventilation

27
Leakage from deteriorated galvanized water pipes

28
Ponding water to a newly constructed box gutter

29
Gaps observed between box gutter and roofing. Metal deck roofing not weathered resulting in water penetration

30
Leakage from bathroom resulting in deterioration to flooring timbers

31
Box gutters with poor overflow provisions almost always fail

32
Active termites and damage to timber frame

33
Metal deck roofing deteriorated where lapped mid span

34
Box gutters installed with a change of direction and no provisions for overflow. Leakage is likely to occur

35
Metal deck roofing deteriorated where lapped mid span

36
Deteriorated timber verandah beam due to prolonged water penetration from a roof penetration

37
Deteriorated timber verandah beam due to prolonged water penetration from a roof penetration

38
Undersized box gutters with no overflow provisions almost always fail. Recently built home

39
Structural cracking to brick arch

40
Water penetration from roof

41
Water penetration from bathroom where water proofing is incomplete / non-compliant

42
Water penetration from bathroom where water proofing is incomplete / non-compliant. Underside of drainage grate visible

43
Treated timber retaining walls do deteriorate over time. Generally at the posts

44
Mold growth to flooring in a recently constructed house where subfloor ventilation is poor and condensation forming on stormwater pipes is directed towards the floor frame

45
Mold growth to flooring in a recently constructed house where subfloor ventilation is poor and condensation forming on stormwater pipes is directed towards the floor frame

46
Deterioration to verandah timbers is common

47
Water staining to bathroom flooring indicates leakage from the shower area

48
Brick piers settled

49
DIY plumbing waste pipes separated at the joins

50
Leakage from shower. Floor joists and bearers are extensively deteriorated and no longer supporting the floor

51
Building subsidence resulting in cracking to brickwork

52
Ponding water under house

53
Mold growth and deterioration to flooring due to poor subfloor ventilation

54
Brick pier deterioration

55
Brick pier deterioration

56
Undersized box gutters with no overflow provisions almost always fail

57
Extensively deteriorated particleboard flooring due to prolonged leakage from the shower area

58
Parapet walls deteriorated

59
Fibrous sheet flooring not adequately supported where joined under a drainage grate

60
Deteriorated metal pier

61
Deteriorated metal pier

62
Deteriorated metal piers

63
Mold growth to wall linings due to penetrating damp issues

64
Extensively deteriorated particleboard flooring due to prolonged leakage from the shower area

65
Deteriorated timber bargeboards

66
Eaves linings incomplete

67
Deteriorated pergola timbers is common

68
Deteriorated wall frame, skirting boards due to prolonged leakage from the adjacent bathroom

69
Rangehood ducting out of alignment

70
Mold growth and deterioration to timber bearer due to poor subfloor ventilation

71
Leaking water pipe joins

72
Water staining and calcification indicates leakage from the bathroom

73
Termite damage to wall frame

74
Termite leads to the brickwork under a bathroom

75
Termite leads to the brickwork under a bathroom

76
Deteriorated ducting

77
Termite damage to timber flooring

78
Asbestos debris under the house

79
Termite damage to particleboard flooring

80
Termite damage to wall frame

81
This termite working was found through a small gap in the brickwork at a suspended garage slab

82
Borer damage to a timber floor joist

83
Termite damage to a roof truss

84
Termite damage to wall frame

85
Termite damage to wall frame

86
Termite damage to a roof beam

87
Termite damage / activity to wall frame

88
Termite damage to a floor joist

89
Termite nest to a tree

90
Termite damage to a roof beam

91
Termite damage to a wall frame

92
Termite workings in a cupboard

93
Termite damage to a floor joist

94
Termite workings / damage in a cupboard

95
Termite damage to a floor bearer

96
Termite damage to a floor bearer

97
Termite damage to particleboard flooring

98
Termite damage to a roof truss
01 / 98
Leakage from bathroom
Leakage from bathroom

01
Leakage from bathroom
Leakage from bathroom

02
Leakage from bathroom

03
Undersized box gutters with no overflow provisions almost always fail

04
Leakage from galvanized water pipes

05
Deteriorated roof sarking

06
Poor subfloor drainage resulting in concrete pier rotation

07
Poor subfloor drainage

08
No roof flashings installed at the chimney

09
Mold growth to timber floor joists where subfloor ventilation is poor

10
Deteriorated timber flooring due to poor subfloor ventilation and fungal growth

11
Deteriorated metal roofing and water proofing membrane

12
Undersized box gutters with no overflow provisions almost always fail

13
Ponding water to box gutter could cause gutters to deteriorate prematurely

14
Deteriorated Box gutter due to ponding water caused by negative fall

15
Leakage from water pipe in the wall cavity

16
Mold growth to flooring due to poor subfloor ventilation

17
Mold growth and deterioration to flooring due to poor subfloor ventilation

18
Mold growth and deterioration to flooring due to poor subfloor ventilation

19
Mold growth to carpet due to prolonged exposure to damp conditions

20
Leakage frombathroom

21
Mold growth and deterioration to flooring due to poor subfloor ventilation

22
Mold growth and deterioration to flooring due to poor subfloor ventilation

23
Mold growth and deterioration to flooring due to poor subfloor ventilation

24
Mold growth and deterioration to flooring due to poor subfloor ventilation

25
Mold growth and deterioration to flooring due to poor subfloor ventilation

26
Mold growth and deterioration to flooring due to poor subfloor ventilation

27
Leakage from deteriorated galvanized water pipes

28
Ponding water to a newly constructed box gutter

29
Gaps observed between box gutter and roofing. Metal deck roofing not weathered resulting in water penetration

30
Leakage from bathroom resulting in deterioration to flooring timbers

31
Box gutters with poor overflow provisions almost always fail

32
Active termites and damage to timber frame

33
Metal deck roofing deteriorated where lapped mid span

34
Box gutters installed with a change of direction and no provisions for overflow. Leakage is likely to occur

35
Metal deck roofing deteriorated where lapped mid span

36
Deteriorated timber verandah beam due to prolonged water penetration from a roof penetration

37
Deteriorated timber verandah beam due to prolonged water penetration from a roof penetration

38
Undersized box gutters with no overflow provisions almost always fail. Recently built home

39
Structural cracking to brick arch

40
Water penetration from roof

41
Water penetration from bathroom where water proofing is incomplete / non-compliant

42
Water penetration from bathroom where water proofing is incomplete / non-compliant. Underside of drainage grate visible

43
Treated timber retaining walls do deteriorate over time. Generally at the posts

44
Mold growth to flooring in a recently constructed house where subfloor ventilation is poor and condensation forming on stormwater pipes is directed towards the floor frame

45
Mold growth to flooring in a recently constructed house where subfloor ventilation is poor and condensation forming on stormwater pipes is directed towards the floor frame

46
Deterioration to verandah timbers is common

47
Water staining to bathroom flooring indicates leakage from the shower area

48
Brick piers settled

49
DIY plumbing waste pipes separated at the joins

50
Leakage from shower. Floor joists and bearers are extensively deteriorated and no longer supporting the floor

51
Building subsidence resulting in cracking to brickwork

52
Ponding water under house

53
Mold growth and deterioration to flooring due to poor subfloor ventilation

54
Brick pier deterioration

55
Brick pier deterioration

56
Undersized box gutters with no overflow provisions almost always fail

57
Extensively deteriorated particleboard flooring due to prolonged leakage from the shower area

58
Parapet walls deteriorated

59
Fibrous sheet flooring not adequately supported where joined under a drainage grate

60
Deteriorated metal pier

61
Deteriorated metal pier

62
Deteriorated metal piers

63
Mold growth to wall linings due to penetrating damp issues

64
Extensively deteriorated particleboard flooring due to prolonged leakage from the shower area

65
Deteriorated timber bargeboards

66
Eaves linings incomplete

67
Deteriorated pergola timbers is common

68
Deteriorated wall frame, skirting boards due to prolonged leakage from the adjacent bathroom

69
Rangehood ducting out of alignment

70
Mold growth and deterioration to timber bearer due to poor subfloor ventilation

71
Leaking water pipe joins

72
Water staining and calcification indicates leakage from the bathroom

73
Termite damage to wall frame

74
Termite leads to the brickwork under a bathroom

75
Termite leads to the brickwork under a bathroom

76
Deteriorated ducting

77
Termite damage to timber flooring

78
Asbestos debris under the house

79
Termite damage to particleboard flooring

80
Termite damage to wall frame

81
This termite working was found through a small gap in the brickwork at a suspended garage slab

82
Borer damage to a timber floor joist

83
Termite damage to a roof truss

84
Termite damage to wall frame

85
Termite damage to wall frame

86
Termite damage to a roof beam

87
Termite damage / activity to wall frame

88
Termite damage to a floor joist

89
Termite nest to a tree

90
Termite damage to a roof beam

91
Termite damage to a wall frame

92
Termite workings in a cupboard

93
Termite damage to a floor joist

94
Termite workings / damage in a cupboard

95
Termite damage to a floor bearer

96
Termite damage to a floor bearer

97
Termite damage to particleboard flooring

98
Termite damage to a roof truss
- Severe building defects showing termite damage in wood beams
- Corroded wall tie visible through building defects in brickwork
- Termite damage to wooden floor joists and building defects.
- Screwdriver inserted into building defects in attic trusses
- Screwdriver inserted into building defects in wooden beam.
- Screwdriver inserted into building defects in wood beam
- Screwdriver probing building defects in a ceiling beam
- Cracked wooden beam showing building defects and rot.
- Screwdriver inserted into a wooden beam to check for building defects.
- Large gum tree with a hollow in a wooded landscape.
- Screwdriver inserted into a crack in a wood building defect.
- Termite-damaged wooden framing showing building defects
- Termite mud tubes on walls, a common building defect.
- Wood rot and building defects in subfloor framing.
- Termite damage and building defects in a white wall corner.
- Severely rotted wooden floor joist building defects
- Rotting timber joists and building defects under a house
- Building defects showing water damage on particle board ceiling
- Screwdriver left in attic insulation, a building defect.
Thankyou for looking at our building defects images!